PIXCI EB1G2

Without 9-pin connector

PCI Express 2.0 x1 Base Camera Link Frame Grabber

  • 12 V @ 190 mA, 3.3 V @ 130 mA
  • Average power consumption: 2.709 Watts
  • 8.38 cm long, 6.88 cm high, 3.30” long by 2.71” high
  • 48 grams, 1.7 ounces
  • 0 to 70 degrees Celsius operation
  • CE, FCC, & ROHS Compliant
  • Accepts camera pixel clocks from 20 to 85 MHz

FEATURES

  • PCIe x1 Gen 2 low-profile desktop frame grabber
  • Operates in any PCI Express slot
  • 5 gigabit per second burst transfer rate
  • 409 megabytes per second sustained transfer rate
  • One 26-pin MDR Camera Link connector
  • Image data DMA transferred to motherboard memory
  • 64-bit memory addressing

CAPTURE

  • From a Base Camera Link camera
  • From line scan or area scan cameras
  • From monochrome or color cameras
  • Individual lines or frames
  • Continuous video
  • Triggered image sequences

TRIGGER AND I/O

  • Camera exposure and asynchronous reset control
  • Trigger and frame enable inputs
  • Strobe output
  • General purpose inputs and outputs

OPTIONS

  • Standard or low-profile bracket available
  • Optional standard height bracket with Dsub for trigger,etc.

SPECIFICATIONS

Signal Input & OutputEIA RS-644 (LVDS) Drivers & Receivers support pixel clock frequencies up to 85 MHz
PerformanceSupports the camera’s maximum:
– Horizontal Resolution
– Vertical Resolution
– Frame Rate
– Bit Depth
Connections– One 26-pin 3M MDR Camera Link connector for Base.
– 9-pin connector for Trigger, Frame Enable, Strobe, and General Purpose I/O.
– Camera Link cables available.
Data Transfers– Supports cameras with data output rates up to 409 MBytes/second (performance may vary depending on computer system capabilities)
– 64-bit memory addressing
Bus Requirements– PCI Express x1 Gen 2 or better slot.
– Operates in PCI Express x16, x8, x4, or x1 slot.
Dimensions8.38 cm long by 6.88 cm high (3.30″ long x 2.71″ high)
Certifications– CE Compliant
– ROHS Compliant
EPIX SOFTWARE Support
– Supported by XCAP-Lite (no charge with board purchase), XCAP-Ltd, XCAP-Std, XCLIB, and PXIPL.
– Compatible with 32-bit & 64-bit Windows 11, 10, 8, 7, Vista, XP, 2000, LINUX, and 32-bit DOS. Also TWAIN and Image-Pro Compatible.
– Windows Media Foundation Frame Server (DirectShow) and Video for Linux (V4L2) source drivers are distributed with all versions of XCAP.

SOFTWARE

  • XCAP-Lite image capture, display, and save program included with frame grabber purchase
  • XCAP-LTD captures video to computer memory
  • XCAP-STD streams video to disk and performs image processing
  • XCAP supports all camera link cameras connected to PIXCI® frame grabbers
  • XCLIB programmer libraries for frame grabber and camera control
  • PXIPL image processing, measurement, and analysis libraries
  • Windows & Linux, 32 & 64-bit
  • TWAIN compatible